<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\ErrorsStyleSheet.xsl"?>
<Error>
<ErrorNumber>2202</ErrorNumber>
<ErrorFamily>Non-Volatile Storage</ErrorFamily>
<ErrorMessage>
NVS: subscan size nvs config parameter is invalid
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>All</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
This message idicates that the sub-scan size in NVS config section was greater than the
machine can handle. Make sure the parameter is setup correctly. If the customer needs to
image something larger, he will need to purchase a upgrade or a larger format machine.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
Record error message and contact Creo Service
</text></DescriptionText>
</OperatorAction>
<Cause>
Improper setup of NVS parameters:config.sscan
</Cause>
<Cause>
Improper setup of NVS parameters:sys.maxssz
</Cause>
<SeeAlso>
<UnnumberedList>
<Link><LinkAddress>../nvs/config_cfg_ssz.xml</LinkAddress><LinkTitle>NVS: config ssz</LinkTitle></Link>
<Link><LinkAddress>../nvs/sys_cfg_maxssz.xml</LinkAddress><LinkTitle>NVS: sys maxssz</LinkTitle></Link>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:32:18 2008 PST
</Updated>
<Links>
</Links>
</Error>